Appendix C - Site Test Report, Scotbeef, Bridge of Allan
Report on Radio Frequency Site Measurements at Scotbeef, Longleys Plant Bridge of Allan
CONTENTS
Executive Summary
Acknowledgements
List of Terms and Abbreviations
1 Introduction
1.1 Test Location
1.2 Referenced Standards
2 Testing
2.1 Current Clamp Tests
2.2 Loop Antenna Tests
2.3 Active Receive Antenna
2.4 Typical Emissions Normally Present
2.5 Test Procedure
2.5.1 Description of measurement parameters
2.6 Test areas
2.6.1 Site 1 - Animal Reception
2.6.2 Plots - Site 1
2.6.2.1 9 kHz to 1 MHz - Loop Antenna
2.6.2.2 30 MHz to 1000 MHz - Active Receive Antenna
2.6.3 Site 2 - Entrance to Auction Ring 3
2.6.4 Site 3 - Exit from Auction Ring 3
2.6.5 Plots - Site 2
2.6.5.1 9 kHz to 1 MHz - Loop Antenna
2.6.5.2 1 MHz to 5 MHz - Loop Antenna
2.6.5.3 30 MHz to 1000 MHz - Active Receive Antenna
2.6.6 Plots - Site 3
2.6.6.1 9 kHz to 150 kHz and 150 kHz to 30 MHz - Current clamp
2.6.6.2 9 kHz to 1 MHz - Loop Antenna
2.6.6.3 9 kHz to 150 kHz - Loop Antenna
2.6.6.4 150 kHz to 5 MHz - Loop Antenna
2.6.6.5 120 kHz to 140 kHz - Loop Antenna
2.6.6.6 30 MHz to 1000 MHz - Active Receive Antenna
2.7 Site 4 - Tests During Main Cattle Auction
2.7.1 Plots - Site 4
2.7.1.1 9 kHz to 30 MHz - Current Clamp
2.7.1.2 9 kHz to 150 kHz - Loop Antenna
2.7.1.3 150 kHz to 5 MHz - Loop Antenna
2.7.1.4 100 kHz to 150 kHz - Loop Antenna
2.7.1.5 30 MHz to 1000 MHz - Active Receive Antenna
3 Test Equipment Used
References
List of Tables
Table 1 List of Test Equipment Used
List of Figures
Figure 1 Sheep stunning area - plan view
Figure 2 Cattle stunning area - plan view
Figure 3 RF Measurement 150 kHz to 30 MHz, clamp
Figure 4 RF Measurement 100 kHz to 150 kHz, clamp
Figure 5 RF Measurement 9 kHz to 150 kHz, Parallel
Figure 6 RF Measurement 9 kHz to 150 kHz, Perpendicular
Figure 7 RF Measurement 150 kHz to 5 MHz, Parallel
Figure 8 RF Measurement 150 kHz to 5 MHz, Perpendicular
Figure 9 RF Measurement 5 MHz to 30 MHz, Parallel
Figure 10 RF Measurement 5 MHz to 30 MHz, Perpendicular
Figure 11 RF Measurement 100 kHz to 150 kHz, Parallel
Figure 12 RF Measurement 100 kHz to 150 kHz, Perpendicular
Figure 13 RF Measurement 30 MHz to 1000 MHz, Horizontal
Figure 14 RF Measurement 30 MHz to 1000 MHz, Vertical
Figure 15 Typical RF Measurement 30 MHz to 1000 MHz, Vertical
Figure 16 RF Measurement 9 kHz to 150 kHz, Parallel
Figure 17 RF Measurement 9 kHz to 150 kHz, Perpendicular
Figure 18 RF Measurement 150 kHz to 5 MHz, Parallel
Figure 19 RF Measurement 150 kHz to 5 MHz, Perpendicular
Figure 20 RF Measurement 5 MHz to 30 MHz, Parallel, measure 1
Figure 21 RF Measurement 5 MHz to 30 MHz, Parallel, measure 2
Figure 22 RF Measurement 5 MHz to 30 MHz, Perpendicular, measure 1
Figure 23 RF Measurement 5 MHz to 30 MHz, Perpendicular, measure 2
Figure 24 RF Measurement 100 kHz to 150 kHz, Parallel
Figure 25 RF Measurement 100 kHz to 150 kHz, Perpendicular
Figure 26 RF Measurement 30 MHz to 1000 MHz, Horizontal
Figure 27 RF Measurement 30 MHz to 1000 MHz, Vertical